Features:
- Semi- Conductive/Insulation Double layer Tubing
- Application up to 36kV
- Minimum fully recovery temperature: 130℃
Technical properties
Test Items |
Test Method |
Test Requirements |
Insulation layer |
|
|
Tensile strength |
ASTM D 2671 |
10MPa min. |
Ultimate elongation |
ASTM D 2671 |
200% min. |
Volume resistivity |
IEC 93 |
1014Ω.cm min. |
Water absorption |
ISO 62 |
0.5% max. |
Semi conductive layer |
|
|
Tensile strength |
ASTM D 2671 |
12MPa min. |
Ultimate elongation |
ASTM D 2671 |
200% min. |
Volume resistivity |
ASTM D 257 |
104Ω.cm max. |
Dimensions:
Size |
As Supplied |
After Recovery |
Standard |
|
(mm) |
(mm) |
(mm) |
length(m) |
|
|
D* (Min.) |
d*(Max.) |
w(Min.) |
|
36/12 |
36 |
12 |
5.4 |
1.0-1.2 |
45/15 |
45 |
15 |
5.4 |
1.0-1.2 |
55/18 |
55 |
18 |
5.4 |
1.0-1.2 |
65/22 |
65 |
22 |
6 |
1.0-1.2 |
73/26 |
73 |
26 |
6 |
1.0-1.2 |
85/30 |
85 |
30 |
6 |
1.0-1.2 |
95/34 |
95 |
34 |
6 |
1.0-1.2 |
100/38 |
100 |
38 |
6 |
1.0-1.2 |
115/34 |
115 |
34 |
6 |
1.0-1.2 |
120/45 |
120 |
45 |
6.1 |
1.0-1.2 |
D* = Inner diameter as supplied
d* = Inner diameter after fully recovered