Anticorrosive Coating for Towers


Anticorrosive coating for towers is a two-component, thick-type, one-side polyurethane acrylic coating with excellent weather resistance and long recoating performance. This product has both anti-corrosion, weather resistance in one, with excellent wear resistance, impact resistance, color retention and aging resistance.


Product Features

  • The construction is safe and convenient, and the surface treatment requirements are low
  • Primer painting and finished painting designing into one, cost-effective, save labor and materials
  • Environmental friendly and pollution-free, in line with the international environmental protection requirements


Applications

  • Anticorrosion protection of steel tower structure in new construction or maintenance
  • Anticorrosion protection of other steel structures in various corrosive environment

Technical Parameters

Test Item

Test Standards

Typical Value

Appearance

JG/T 224-2007

Gray

Solid content, (%)

GB1725-79

55

surface dry,(h)

GB/T 1728–1979(1989)

1.5

Entity dry,(h)

GB/T 1728–1979(1989)

5.5

Adhesion (grid method/grade)

GB/T 9286-98

0

Bending resistance (mm)

JG/T 224-2007

2

Impact resistance (mm)

JG/T 224-2007

40

Resistance to water

GB1733-93

168h no abnormalities

Aging test

JG/T 224-2007

no crack, powder ≤ level 1; Discolor≤ level 2

Resistance to salt spray

JG/T 224-2007

750h no flake no red rust

Acid resistance (5%H2SO4)

JG/T 224-2007

500h without exception

Salt resistance water (3%NaCl)

JG/T 224-2007

500h without exception

Workability.

JG/T 224-2007

Brush two lines without obstacles

Environmental performance

RoHS 2.0

Qualified

 

Direction for Use

1, Surface treatment: Clean up rust, burr, oil, dust, the surface should be flat, dry, no loose floating rust, old coating film, oxide scale, rust removal grade should reach ST2 level and above.

2, A, B components in accordance with the use of the proportion of mixing, stirring uniform can be constructed, according to different construction methods and site environmental conditions in the paint to add the appropriate amount of diluent deployment to the appropriate viscosity, so that the paint can be fully infiltrated but does not produce leakage, hanging, loose, peeling and other defects.

3, The tower site coating construction should be carried out from top to bottom. The coating method can be applied by brushing or spraying.


Product Specification

21kg / set (including component A 17.5kg/barrel, component B 3.5kg/barrel)

3kg / set (including component A 2.5kg/ barrel, component B 0.5kg/barrel)


Certificate






Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related products
Visco-Elastic Self-adhesive Corrosion Protection Tape
Viscoelastic Anti-Corrosion Adhesive Tape
The viscoelastic anti-corrosion adhesive tape is an ideal anti-corrosion product. Widely used in corrosion prevention and repair of the anti-corrosion coating of oil and natural gas pipelines, repair of damaged 3PE anti-corrosion coating, and corrosion protection of irregular equipment such as flanges, valves and pumps. It has unique cold flow property and can repair itself during anti-corrosion and repairing process to achieve complete protection. Due to the excellent chemical resistance and no peel-off of the cathodic protection layer, the product can completely eliminate water intrusion and microbial corrosion and thus ensure unique long-term effect.
Industrial PE Anti Corrosion Adhesive Tape
PE Anti-Corrosion Adhesive Tape
PE anticorrosive adhesive tape is mainly used in oil and gas transmission; Chemical industry, urban construction of water supply and drainage and gas transmission, etc. The outer surface of the buried steel pipeline corrosion. Construction is convenient, no pollution and other characteristics, is outside the pipe anticorrosion priority of anticorrosive system. The performance indicators of the product fully meet the provisions of CNPCstandard SY/T0414-2017 and American Industrial Association standards ANSI/AWWAC209-00 and NACEMR0274-95. The product has reached the level of similar products at home and abroad.
Anti-corrosion Primer
Primer for Anti-Corrosion Tape
The anticorrosive primer and PE anticorrosive tape together constitute the polyethylene cold wound anticorrosive system. Coated on the surface treatment of steel tube, can fill a small bump on the surface of the steel tube, and can increase the adhesive tape with sticky relay between steel tube, at the same time it is also a kind of excellent corrosion inhibitor.
Thermal conductive Insulating Tape
EPR Electrical Semi-conducting Tape KC72

◆ Can be used to repair XLPE cable terminations and joints or shielding for other devices up to 110kV.

◆ Retains its conductivity when stretched.

◆ Semi-conducting (low resistivity).

◆ Suitable for irregular shapes cable with good elongation.

◆ Withstand high temperatures (130°C/266°F) short-term overload.

◆ Compatible with all solid dielectric cable insulations and conductors.

◆ Resistance to ozone, solvents, UV, xenon exposure and moisture.

◆ Suitable for indoor or outdoor applications.

◆ Operation and installation easily.

◆ Increases its conductance and will not harm it in any way.

fire retardant blanket
Heat-absorbing and Fireproof Blanket KC9000
KC9000 heat-absorbing and fireproof blanket is a fireproof product that can be directly coated on the external protection of equipment, power cable, cable bridge, etc., which can effectively prevent flame spread and reduce the serious damage caused by high temperature conduction.
High Precision insulating joint
64/110KV YJZGG Prefabricated Insulating Joint/ Straight Through Joint For 64/110kv Xlpe Cable

1. The body of joint is made of imported silicone rubber with good quality, so it is with high strength, elasticity and tear resistance as well as excellent thermal

aging resistance.

2. The body of joint has integral pre-fabricate structure with high voltage shielded, stress cone and insulating injection pressed integration, so it has excellent properties and easy to test as well as install.

3. The body of joint is analized and computed optimization by finite element software, so it has more resonable field-intensity distribution and high insulation safety margin.

4. The body of insulating joint and straight through joint is the same, the d ifference is just the handling of shielding on-site installation, insulating joint with one side insulated and the rest shielded while staight through joint full shielded.

5. The joint has completely sealed structure with high mechanical strength and good sealing performance.

6. Joint protecting is made of insulating copper case with high-intensitive T2 copper, and the moulded high-density PE material of its external surface is used for insulation and anti-corrosion with good mechanical protection and permanent waterproof sealing performance, which ensure the joint to run safely and reliably in the long-term under harsh environment.In addition, it can equip glass fiber reinforced plastic protective box as a strengthen waterproof measure accordingly.

7. Special installer tools make the installation more convenient.

Elbow Surge Arrester
Elbow Surge Arrester (6~15kV)

Applications:

suitable for American 200A electrical system, installed on the 200A interface of the high voltage outlet of American box substation, ring main cabinet, cable branch box, buried transformer and other electrical equipment to provide overvoltage protection for electrical equipment.

The product interface complies with the 200A casing design in the standard IEEE386.


Water Proofing Butyl Tape
Self-adhesive Water Proofing Butyl Tape KC101
◆ High adhesion

◆ Weather resistance

◆ High flexibility

◆ High elongation at break

Subscribe
Subscribe to our newsletter and stay up to date with the latest news and deals !

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

About

contact