Electrical Insulating Filler Tape KC78

High tensile strength and bonding strength.
Suitable for irregular shapes cable with good elongation.
Ensuring high quality seal over a wide range of temperatures.
Physical and electrical properties are unaffected by the degree of stretch.
Self-fusing tape.
Good chemical resistance, weather resistance and corrosion resistance.
Excellent ageing properties.
Excellent electrical properties.
Operation and installation easily.

Cotran Brand KC78 Electrical Insulation Filler Tape is a conformable, flexible, self-fusing butyl-based, waterproofing mastic tape. It provides excellent resistance to varying weather, aging, and it also provides excellent adhesion to metals, cable insulations and jacket. This product can be used in sealant as a waterproofing filler for low voltage cable terminations and joints. 


Applications

◆ To insulate low-voltage (below 600V) connections.
◆ To build up cable splices and fill out major irregularities and voids in low-voltage splices (below 2300V).
◆ To create a uniform base in irregular cable end for further overwrapping.
◆ To smooth bus bar irregularities.
◆ To be a moisture seal at grounding wire.
◆ To be a sealant with excellent adhesion to cable jackets and other insulating materials.


Test Parameters

No.

Test Item

Result

Test Method

1

Color

Black

 

2

Thickness

3.18mm

 

3

Tensile Strength

3.72N/10mm

ASTM D1000

4

Elongation at Break

>602%

ASTM D1000

5

Insulation resistance

1.53x1013 Ώ.cm

ASTM D1000

6

Copper corrosion

None

ASTM D69


Installation

Cotran Brand KC78 eletrical insulation filler tape should be applied in successive half-lapped, level-wound layers until desired build-up is reached.

Step 1 Wipe off the dusts on the splice area before wrapping.

 

Step 2 Remove the liner and stretch the tape to 1 to 2 times of its original length, apply the tape in 50%-lapped with mastic side toward area to the wrapped. Stretching the tape to 4 times of its original length is not recommended.

 

Step 3 Finish breaking the tape by holding it with your thumb and stick the end well.

 

Step 4 AfterKC78 electrical insulation filler tape is applied, overwrapping COTRAN PVC insulation tape is recommended, apply 3 layers of COTRAN PVC insulation tape in a 50% overlapping with no tension. Make sure not to overstretch the PVC tape during installation.

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related products
Wraparound Repair Sleeve
Wraparound Repair Sleeve

Cotran wraparound repair sleeve (CWRS) is designed to repair damaged cable jackets and protect cable or pipes where needs corrosion protection on undamaged ones. CWRS is made from modified cross-linked polyolefin (XLPE) with a hot-melt adhesive. When heating, the sleeve shrinks and the adhesive melts, thereby achieving tightly bonding between the sleeve and the cable. It provides an excellent solution of protection against mechanical stress, harshest environments, moisture and corrosion.

CWRF is a fiber reinforced repair sleeve, which is composed of XLPE and fiber layer. It can provide better mechanical properties. CWRA is a fiber reinforced and aluminum layer reinforced repair sleeve, which is composed of XLPE, fiber layer, and aluminum layer. It can provide more stronger mechanical properties than CWRS and CWRF.

Foam Sealing Material
Foam Sealing Material KC5000

KC5000 foam sealing material is made of A and B material after proper proportion of mixing, chemical reaction and form foaming body. Before it becomes a foaming body, the product is in liquid form and has good fluidity. It can be extremely well applied to fire proof and moisture-proof plugging at the bottom of various electrical and communication panels and cabinets, fire proof and moisture-proof plugging at the opening of complex perforating pipe fittings, etc. The foam sealing material by fire, heat and other high temperature will produce expanded carbon layer, can effectively prevent the spread of fire combustion and heat transfer, so it can provide good protection for non-fire surface, according to GB 23864-2009 standard requirements, with a 1.5h fire aging. In addition, the product in the harsh, dirty environment, still can maintain the normal fire and moisture-proof function.

Aluminum Water Cooling Plate
Power Battery Pack Aluminum Water Cooling Plate

◆High production efficiency

◆Large thermal transfer area

◆Flexible flow channel design

◆Rapid thermal cooling speed

◆Thin thickness to save space

◆Easy processing and shaping

◆Goodthermal exchange effect

◆Low leak risk and high security

Quick-Locking Hose Clamp
Quick-Locking Hose Clamp en-CST
The Hose Clamp is used to mountequipmentto poles and tubes, compatible with slotted profiles and can be installed on cable ladders, brackets, I-beams and tubes.
Oil Resistant Filling Mastic
Oil Resistant Filling Mastic

Applications:

To provide oil resistance, void filling and sealing for oil-immersed cable termination and joints for heat shrink technology up to 36kV.

Battery Pack Liquid Cold Plate
New Energy Vehicle Battery Pack Liquid Cold Plate

◆Flexible flow channel design

◆Thin thickness to save space

◆Easy processing and shaping

◆Large thermal dissipation area

◆High heat dissipation efficiency

◆Low leakage risk and highsafety

◆Good pressure resist and strength

◆High production efficiency and yield

Flexible Cold Shrink Tube
Customized silicone rubber cold shrink tube enRR-CST

IPX8 class, stable and long-life during operation

Easy to install, only two steps (Cover, pull)

Fast installation, only 15-30 seconds needed to seal one connection

No limitation of spare space, especially design for MIMO &massive MIMO Antenna, also convenient to deploy on wall-mounted, high tower, pole-mounted condition etc.,

Easy to uninstall, only need knife to cut tube open

No skill required by engineers, uniform quality after installation, stable and good sealing and weatherproofing performance

Much time cost, and labor cost saving

Good operating capability under extreme cold and hot condition, highland, salt-mist situation, heavy windy weather, and anti-UV, anti-ozone


Fire Retardant Coating for Electrical Cables
Cable Fireproof Coating KC2000

◆ Completely meet the requirements of GB 28374-2012;

◆ Environmental protection halogen-free, non-toxic and harmless;

◆ Good flexibility;

◆ Good insulation performance;

◆ Strong adhesion;

◆ Good fire protection effect;

◆ Good anti-corrosion performance.

Subscribe
Subscribe to our newsletter and stay up to date with the latest news and deals !

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

About

contact