Cotran KC96-Dual is developed based on the standard KC96 EPDM cold shrink tube, It aims to make sealing and weatherproofing more reliable and stable, and to improve the installation efficiency and performance. With the dual layers structure, built-in silicone tube, no need foam tape or other filling materials any more.
Properties Advantage
- High elastic EPDM and silicone rubber materials.
- Better weatherproofing performance with double-layer structure
- Good puncture resistant, abrasion resistance, acid and alkali resistance.
- 20 years long lifetime during operation.
- Easy to install, only two steps (Cover, pull).
- Fast installation, only 15-30 seconds needed to seal one connection.
- No limitation of spare space, especially design for narrow space.
- No skill required by engineers, uniform quality after installation, stable and good sealing and
- Weatherproofing performance.
- Much time and labor cost saving.
- Good operating capability under hash environmental condition, salt-mist situation, heavy windy weather, and anti-UV, anti-ozone.
Applications
◆ Protection and repair for outer sheath of high voltage cable joint;
◆ Fire protection of cables and connectors;
◆For all base materials that need to be insulated against fire;
Step 1 |
|
1. Wrap the foam tape on the 1/2’’ cable to expand the application outline 2. Put jumper cable inside of the tube, before connectjumper to equipment 3. Arrow symbol will be direction of pulling strip, which usually should be downward |
|
Step 2 |
|
|
1.Hold the tube, pull strip downward, and rolling, slowly by slowly |
Step 3 |
|
1. Hold the foam tape part tightly, clench several times toaccelerate foam tape attached on cables, help EPDM tube shrinking. |
Property
Item |
Parameter and Result |
Test Method |
|
Waterproof |
Class |
Pass, IPX8 |
IEC 60529:1989+A1:1999+A2:2013; 1 meter depth in water, duration: 4 hours |
Physical and mechanical properties |
Shore Hardness |
A/37/1 |
ASTM D2240-15 |
Tensile Strength |
11.75 MPa |
ASTM D412-15a Method A |
|
Elongation |
770% |
ASTM D412-15a Method A |
|
Tear Strength |
31.71 KN/m |
ASTM D624-00(2012) |
|
Electricity |
Dielectric Strength |
22.4 KV/mm |
ASTM D149-09(2013) Method A |
Material |
Environmental protection |
RoHS |
IEC 62321 |
Models
Model |
Color |
Cable Size(mm) |
Package |
KC96-Dual Ф40-140 |
Black (color can be customized) |
Dual-Layerstructure,design for 1/2” jumper (7/16 DIN) to Equipment |
50 pcs/carton |
KC96-Dual Ф28-140 |
Black (color can be customized) |
Dual-Layerstructure,design for 4.3-10 jumper to Equipment |
50 pcs/carton |